Underground Pipe Gas Leak Detector LT-828

Short Description:

Model: LT-828Applications:LT-828 Underground Pipe Gas Leak Detector is an ideal instrument for pinpointing underground pipeline gas leaks, such as Natural gas, liquefied petroleum gas (LPG), artificial coal gas and so on. It can measure combustible gas, CO, O2, H2S. LT-828 is widely used in the...


Product Detail

Product Tags

Model: LT-828

Applications:
LT-828 Underground Pipe Gas Leak Detector is an ideal instrument for pinpointing underground pipeline gas leaks, such as Natural gas, liquefied petroleum gas (LPG), artificial coal gas and so on. It can measure combustible gas, CO, O2, H2S. LT-828 is widely used in the department of town gas, petrochemical, oil depot, oil and gas field and so on.

Characteristic:
LT-828 Underground Pipe Gas Leak Detector is characterized by high sensitivity and good selectivity. You needn’t drill, you can detect the buried pipeline and leak point directly.
Battery: high capacity lithium battery, intelligent charging quickly, without human control, saving the cost
Sensor and the air pump: The most advanced one in the world
anti-interference, low temperature resistant, high stability.
Voice Alerts:
It changes according to gas concentration. You needn’t observe display. Then work efficiency has been improved.
The gases from dozens of meters could be inhaled into the included getter pump instrument and then detected.
It has a self-inspection to display, battery, sensor and acousto-optic alarm function while started or needed.

key technical indicators
Detecting gas: suitable for natural gas, liquefied petroleum gas, artificial gas.
Detecting gas type: combustible gas, carbon monoxide, oxygen, hydrogen sulfide
Sensitivity: in 0~1000ppm, it is better than 50ppm; in 1~100%LEL, it is better than 1%LEL
Detection range: 0~1000ppm, 1-100%LEL (automatic)

Gas

Range

Accuracy

CH4

(0.00~1.00)% CH4

±0.10%CH4

(1.00 ~3.00)% CH4

±10%

(3.00~4.00)% CH4

±0.30%CH4

O2

(0~30)% O2

±3.0%

CO

(0~100)×10-6 CO

Less than ±(1.5+2.0%)

(100~500)×10-6 CO

Less than±4.0%

>500×10-6CO

Less than10.0%

H2S

(0~49)×10-6 H2S

±3×10-6 H2S

(50~100)×10-6 H2S

±10%

Technical Specification:

Detection Range

0-1000ppm

intrinsic error

<±3%(F.S)

warm-up time

10s

Minimum Reading

1%LEL

Sensor life

36 months

Battery run

15 hours

Response Time

<10s

Batteries

4400mAh 7.4V

surrounding air speed

<2m/s

Gas flow

1L/min

dimension

180mm×110mm×80mm

Weight

1kg (with charger)


  • Previous:
  • Next:

  • Write your message here and send it to us